summaryrefslogtreecommitdiffstats
path: root/man1p/tabs.1p
blob: a64978ca770fb9eb19c52ad7ba002c1f77e97760 (plain) (blame)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
.\" Copyright (c) 2001-2003 The Open Group, All Rights Reserved 
.TH "TABS" P 2003 "IEEE/The Open Group" "POSIX Programmer's Manual"
.\" tabs 
.SH NAME
tabs \- set terminal tabs
.SH SYNOPSIS
.LP
\fBtabs\fP \fB[\fP \fB-\fP\fIn\fP\fB| -a| -a2| -c| -c2| -c3| -f| -p|
-s|
-u\fP\fB][\fP\fB+m\fP\fB[\fP\fIn\fP\fB]]\fP \fB\fP\fB[\fP\fB-T\fP
\fItype\fP\fB]\fP\fB
.br
.sp
tabs\fP \fB[\fP\fB-T\fP \fItype\fP\fB][\fP \fB+\fP\fB[\fP\fIn\fP\fB]]\fP
\fIn1\fP\fB[\fP\fB,\fP\fIn2\fP\fB,...\fP\fB]\fP\fB\fP
\fB
.br
\fP
.SH DESCRIPTION
.LP
The \fItabs\fP utility shall display a series of characters that first
clears the hardware terminal tab settings and then
initializes the tab stops at the specified positions   \ and optionally
adjusts the margin. 
.LP
The phrase "tab-stop position \fIN\fP" shall be taken to mean that,
from the start of a line of output, tabbing to position
\fIN\fP shall cause the next character output to be in the ( \fIN\fP+1)th
column position on that line. The maximum number of tab
stops allowed is terminal-dependent.
.LP
It need not be possible to implement \fItabs\fP on certain terminals.
If the terminal type obtained from the \fITERM\fP
environment variable or \fB-T\fP option represents such a terminal,
an appropriate diagnostic message shall be written to standard
error and \fItabs\fP shall exit with a status greater than zero.
.SH OPTIONS
.LP
The \fItabs\fP utility shall conform to the Base Definitions volume
of IEEE\ Std\ 1003.1-2001, Section 12.2, Utility Syntax Guidelines,
\ except for
various extensions: the options \fB-a2\fP, \fB-c2\fP, and \fB-c3\fP
are multi-character. 
.LP
The following options shall be supported:
.TP 7
\fB-\fP\fIn\fP
Specify repetitive tab stops separated by a uniform number of column
positions, \fIn\fP, where \fIn\fP is a single-digit
decimal number. The default usage of \fItabs\fP with no arguments
shall be equivalent to \fBtabs\fP-8. When \fB-0\fP is used,
the tab stops shall be cleared and no new ones set.
.TP 7
\fB-a\fP
1,10,16,36,72
.br
Assembler, applicable to some mainframes. 
.TP 7
\fB-a2\fP
1,10,16,40,72
.br
Assembler, applicable to some mainframes. 
.TP 7
\fB-c\fP
1,8,12,16,20,55
.br
COBOL, normal format. 
.TP 7
\fB-c2\fP
1,6,10,14,49
.br
COBOL, compact format (columns 1 to 6 omitted). 
.TP 7
\fB-c3\fP
1,6,10,14,18,22,26,30,34,38,42,46,50,54,58,62,67
.br
COBOL compact format (columns 1 to 6 omitted), with more tabs than
\fB-c2\fP. 
.TP 7
\fB-f\fP
1,7,11,15,19,23
.br
FORTRAN 
.TP 7
\fB-p\fP
1,5,9,13,17,21,25,29,33,37,41,45,49,53,57,61
.br
PL/1 
.TP 7
\fB-s\fP
1,10,55
.br
SNOBOL 
.TP 7
\fB-u\fP
1,12,20,44
.br
Assembler, applicable to some mainframes. 
.TP 7
\fB-T\ \fP \fItype\fP
Indicate the type of terminal. If this option is not supplied and
the \fITERM\fP variable is unset or null, an unspecified
default terminal type shall be used. The setting of \fItype\fP shall
take precedence over the value in \fITERM .\fP
.sp
.SH OPERANDS
.LP
The following operand shall be supported:
.TP 7
\fIn1\fP\fB[\fP,\fIn2\fP,...\fB]\fP
A single command line argument that consists of tab-stop values separated
using either commas or <blank>s. The
application shall ensure that the tab-stop values are positive decimal
integers in strictly ascending order. If any number (except
the first one) is preceded by a plus sign, it is taken as an increment
to be added to the previous value. For example, the tab
lists 1,10,20,30 and 1,10,+10,+10 are considered to be identical.
.sp
.SH STDIN
.LP
Not used.
.SH INPUT FILES
.LP
None.
.SH ENVIRONMENT VARIABLES
.LP
The following environment variables shall affect the execution of
\fItabs\fP:
.TP 7
\fILANG\fP
Provide a default value for the internationalization variables that
are unset or null. (See the Base Definitions volume of
IEEE\ Std\ 1003.1-2001, Section 8.2, Internationalization Variables
for
the precedence of internationalization variables used to determine
the values of locale categories.)
.TP 7
\fILC_ALL\fP
If set to a non-empty string value, override the values of all the
other internationalization variables.
.TP 7
\fILC_CTYPE\fP
Determine the locale for the interpretation of sequences of bytes
of text data as characters (for example, single-byte as
opposed to multi-byte characters in arguments).
.TP 7
\fILC_MESSAGES\fP
Determine the locale that should be used to affect the format and
contents of diagnostic messages written to standard
error.
.TP 7
\fINLSPATH\fP
Determine the location of message catalogs for the processing of \fILC_MESSAGES
\&.\fP 
.TP 7
\fITERM\fP
Determine the terminal type. If this variable is unset or null, and
if the \fB-T\fP option is not specified, an unspecified
default terminal type shall be used.
.sp
.SH ASYNCHRONOUS EVENTS
.LP
Default.
.SH STDOUT
.LP
If standard output is a terminal, the appropriate sequence to clear
and set the tab stops may be written to standard output in
an unspecified format. If standard output is not a terminal, undefined
results occur.
.SH STDERR
.LP
The standard error shall be used only for diagnostic messages.
.SH OUTPUT FILES
.LP
None.
.SH EXTENDED DESCRIPTION
.LP
None.
.SH EXIT STATUS
.LP
The following exit values shall be returned:
.TP 7
\ 0
Successful completion.
.TP 7
>0
An error occurred.
.sp
.SH CONSEQUENCES OF ERRORS
.LP
Default.
.LP
\fIThe following sections are informative.\fP
.SH APPLICATION USAGE
.LP
This utility makes use of the terminal's hardware tabs and the \fIstty\fP
\fItabs\fP
option.
.LP
This utility is not recommended for application use.
.LP
Some integrated display units might not have escape sequences to set
tab stops, but may be set by internal system calls. On
these terminals, \fItabs\fP works if standard output is directed to
the terminal; if output is directed to another file, however,
\fItabs\fP fails.
.SH EXAMPLES
.LP
None.
.SH RATIONALE
.LP
Consideration was given to having the \fItput\fP utility handle all
of the functions
described in \fItabs\fP. However, the separate \fItabs\fP utility
was retained because it seems more intuitive to use a command
named \fItabs\fP than \fItput\fP with a new option. The \fItput\fP
utility does not support setting or clearing tabs, and no known historical
version of
\fItabs\fP supports the capability of setting arbitrary tab stops.
.LP
The System V \fItabs\fP interface is very complex; the version in
this volume of IEEE\ Std\ 1003.1-2001 has a reduced
feature list, but many of the features omitted were restored as XSI
extensions even though the supported languages and coding
styles are primarily historical.
.LP
There was considerable sentiment for specifying only a means of resetting
the tabs back to a known state-presumably the
"standard" of tabs every eight positions. The following features were
omitted:
.IP " *" 3
Setting tab stops via the first line in a file, using -- \fIfile\fP.
Since even the SVID has no complete explanation of this
feature, it is doubtful that it is in widespread use.
.LP
.LP
In an early proposal, a \fB-t\fP \fItablist\fP option was added for
consistency with \fIexpand\fP; this was later removed when inconsistencies
with the historical list of tabs were
identified.
.LP
Consideration was given to adding a \fB-p\fP option that would output
the current tab settings so that they could be saved and
then later restored. This was not accepted because querying the tab
stops of the terminal is not a capability in historical
\fIterminfo\fP or \fItermcap\fP facilities and might not be supported
on a wide range of terminals.
.SH FUTURE DIRECTIONS
.LP
None.
.SH SEE ALSO
.LP
\fIexpand\fP , \fIstty\fP , \fItput\fP , \fIunexpand\fP
.SH COPYRIGHT
Portions of this text are reprinted and reproduced in electronic form
from IEEE Std 1003.1, 2003 Edition, Standard for Information Technology
-- Portable Operating System Interface (POSIX), The Open Group Base
Specifications Issue 6, Copyright (C) 2001-2003 by the Institute of
Electrical and Electronics Engineers, Inc and The Open Group. In the
event of any discrepancy between this version and the original IEEE and
The Open Group Standard, the original IEEE and The Open Group Standard
is the referee document. The original Standard can be obtained online at
http://www.opengroup.org/unix/online.html .